Call or text 9914228811

 

METHODOLOGY FOR FIRE PROTECTION AND SAFETY DESIGN (FPSD)

Client: M/s ___

Title:METHODOLOGY FOR FIRE PROTECTION AND SAFETY DESIGN (FPSD)

24/04/2024

2

Final

AM

SS

YSG

03/03/2022

1

Final

MK

RB

 

Date

Rev

Remarks / Revision Summary

Prepared

Checked

Approved

     

HSE RMSPL

REVISION RECORDS

DISCLAIMER

This methodology has been prepared on behalf of and for the exclusive use of M/s ___ and is subject to and issued in accordance with the contract between M/s ___ and HSE Risk Management Services Private Limited. HSE Risk Management Services Private Limited accepts no liability or responsibility whatsoever for it in respect of any use of or reliance upon this Methodology by any third party.

Copying this Methodology without the permission of M/s ___ or HSE Risk Management Services Private Limited is not permitted.

Proposed Methodology

  • Introduction

Fire protection is the study and practice of mitigating the unwanted effects of potentially destructive fires. It involves the study of the behavior, compartmentalization, suppression and investigation of fire and its related emergencies.

  • Objective

The objective of fire protection and safety design (FPSD) is to prevent fires, detect them early, suppress them effectively, facilitate safe evacuation, ensure structural integrity, and comply with fire safety regulations to protect lives and property in the event of a fire emergency.

  • Methodology
  • To design Foam System as per NFPA-11
  • To design the fire hydrant system as per NFPA-25
  • To design the portable fire extinguisher as per NFPA-10
  • To design the sprinkler system as per NFPA-13
  • To design Dry Chemical Extinguishing Systems for dry chemical systems as per NFPA-17
  • For Installation of Stationary Pumps for Fire Protection as per NFPA-20
  • To design Water Tanks for Fire Protection as per NFPA-22
  • To prepare plant layout evaluation report as per NBC-2005 Rev.2
  • To prepare life safety report as per NFPA-101 Eleventh Edition
  • To design fire alarm system report as per NFPA-72
  • To prepare fire & Gas detection system as per NFPA-72
    • Guideline Used for FPSD Study
  • NFPA-11- for design, installation, operation, testing and maintenance of low, medium & High expansion foam system for fire protection.
  • NFPA-25- is standard for the inspection, testing, and maintenance of water based fire protection system.
  • NFPA-10- Provides requirements to ensure that portable fire extinguishers will work as intended to provide a first line of defense against fire.
  • NFPA-13-addresses sprinkler system design approaches, system installation, and component options to prevent fire deaths and property loss.
  • NFPA-17-This standard includes the minimum requirements to ensure that dry chemical fire extinguishing systems will function as intended throughout their life to protect life and property from fire.
  • NFPA-20- protects life and property by providing requirements for the selection and installation of pumps to ensure that systems will work as intended to deliver adequate and reliable water supplies in a fire emergency.
  • NFPA-22– Provides requirements for the design, construction, installation, and maintenance of tanks and accessory equipment that supply water for private fire protection.
  • NFPA-72- Provides the latest safety provisions to meet society’s changing fire detection, signaling, and emergency communications demands. In addition to the core focus on fire alarm systems, the Code includes requirements for mass notification systems used for weather emergencies; terrorist events; biological, chemical, and nuclear emergencies; and other threats.
    • Project Deliverables

Table 1:FPSD Study

Sr. No.

Document Deliverable

1.

Executive Summary

  •  

Document Review

  •  

FPSD Methodology

  •  

Fire Safety Plan

  •  

Fire Protection System Design Drawings

  •  

Building Modification Recommendations

  •  

Evacuation Plan

  •  

Compliance Documentation

  •  

Training Materials

  •  

Emergency Response Coordination Plan

  •  

Post-Incident Evaluation Reports

  •  

Comments Resolution sheets

  •  

Reference

  •  

List of tables

  •  

List of appendix

  • Software to be used

AutoCAD

About Yashpal singh

Mr. Yashpal Singh is the Managing Director and Process Safety Expert at HSE RMSPL. With 19 years of experience, he specializes in HAZOP, QRA, and functional safety engineering. He helps clients achieve safe, compliant operations while minimizing industrial risks and incidents.

Leave a Comment